Test Code HGB Hemoglobin, Whole Blood
Performing Laboratory
Chilton Hospital Laboratory-HematologyMethodology
Automated Cell CounterSpecimen Requirements
Specimen Type: Whole bloodContainer/Tube: Lavender top (EDTA) or lavender top (EDTA) Microtainer
Specimen Volume: Full tube/Microtainer
Specimen Rejection:
1. Hemolyzed
2. Clotted
3. Diluted with intravenous fluid
4. Tube not filled with minimum volume
Specimen Transport Temperature
AmbientReference Values
Males0 days-2 weeks: 14.5-24.5 g/dL
2 weeks-2 months: 10.7-17.3 g/dL
2 months-3 years: 9.9-14.5 g/dL
3-15 years: 10.9-14.9 g/dL
>15 years: 14.7-16.3 g/dL
Critical values (automatic call-back):
0 days-2 weeks: <10.0 g/dL or >24.5 g/dL
> 2 weeks: <7.0 g/dL or >20.0 g/dL
Females
0 days-2 weeks: 14.5-24.5 g/dL
2 weeks-2 months: 10.7-17.3 g/dL
2 months-3 years: 9.9-14.5 g/dL
3-15 years: 10.9-14.9 g/dL
>15 years: 12.0-14.2 g/dL
Critical values (automatic call-back):
0 days-2 weeks: <10.0 g/dL or >24.5 g/dL
> 2 weeks: <7.0 g/dL or >20.0 g/dL
Day(s) Test Set Up
Monday through SundayAvailable STAT
Turnaround Time:
Routine-4 hours